Greubel, Christoph; Assmann, Walter; Burgdorf, Christian; Dollinger, Günther; Du, Guanghua; Hable, Volker; Hapfelmeier, Alexander; Hertenberger, Ralf; Kneschaurek, Peter; Michalski, Dörte; Molls, Michael; Reinhardt, Sabine; Röper, Barbara; Schell, Stefan; Schmid, Thomas E.; Siebenwirth, Christian; Wenzl, Tatiana; Zlobinskaya, Olga; Wilkens, Jan J. 
Document type:
Zeitschriftenartikel / Journal Article 
Title:
Scanning irradiation device for mice in vivo with pulsed and continuous proton beams 
Journal:
Radiation and Environmental Biophysics 
Volume:
50 
Issue:
Year:
2011 
Pages from - to:
339-344 
Language:
Englisch 
Keywords:
Beam energies ; Beam scanning ; Bragg peaks ; Continuous mode ; Depth dose ; Dose delivery ; Dose verification ; Fluences ; In-vivo ; Micro beams ; Scan range ; Scanning irradiation ; Single-dose ; Treatment planning ; Tumour growth, Experiments ; Irradiation ; Mammals ; Proton beams ; Tumors ; Protons ; Mus ; proton ; animal ; article ; computer assisted radiotherapy ; female ; instrumentation ; Monte Carlo method ; mouse ; pathology ; radiation dose ; radiotherap...    »
 
Abstract:
A technical set-up for irradiation of subcutaneous tumours in mice with nanosecond-pulsed proton beams or continuous proton beams is described and was successfully used in a first experiment to explore future potential of laser-driven particle beams, which are pulsed due to the acceleration process, for radiation therapy. The chosen concept uses a microbeam approach. By focusing the beam to approximately 100 × 100 μm2, the necessary fluence of 109 protons per cm2 to deliver a dose of 20 Gy with...    »
 
ISSN:
0301-634X 
Department:
Fakultät für Luft- und Raumfahrttechnik 
Institute:
LRT 2 - Institut für angewandte Physik und Messtechnik 
Chair:
Dollinger, Günther 
Open Access yes or no?:
Nein / No