Logo
User: Guest  Login
Authors:
Moser, Marcus; Greubel, Christoph; Carli, W.; Peeper, Katrin; Reichart, Patrick; Urban, Benedikt; Vallentin, Thomas; Dollinger, Günther 
Document type:
Zeitschriftenartikel / Journal Article 
Title:
Transport of a high brightness proton beam through the Munich tandem accelerator 
Title of conference publication:
Proceedings of the 14th International Conference on Nuclear Microprobe Technology & Applications 2014 
Journal:
Nuclear Instruments and Methods in Physics Research Section B 
Volume:
348 
Issue:
Conference title:
International Conference on Nuclear Microprobe Technology and Applications (14., 2014, Padua) 
Venue:
Padua 
Year of conference:
2014 
Year:
2015 
Pages from - to:
34-42 
Language:
Englisch 
Keywords:
Proton micro beam ; Beam brightness ; Multicusp source ; Beam transport ; Ion optics 
Abstract:
Basic requirement for ion microprobes with sub-μm beam focus is a high brightness beam to fill the small phase space usually accepted by the ion microprobe with enough ion current for the desired application. We performed beam transport simulations to optimize beam brightness transported through the Munich tandem accelerator. This was done under the constraint of a maximum ion current of 10 μA that is allowed to be injected due to radiation safety regulations and beam power constrains. The main...    »
 
ISSN:
0168-583X 
Department:
Fakultät für Luft- und Raumfahrttechnik 
Institute:
LRT 2 - Institut für angewandte Physik und Messtechnik 
Chair:
Dollinger, Günther 
Open Access yes or no?:
Nein / No