Abstract:
Non-destructive X-ray imaging of thruster parts and assemblies down to the scale of several micrometers is a key technology for electric propulsion research and engineering. It allows for thorough product assurance, rapid state acquisition and implementation of more detailed simulation models to understand the physics of device wear and erosion. Being able to inspect parts as 3D density maps allows insight into inner structures hidden from observation. Generating these density maps and also co...    »
 
Fakultät:
Fakultät für Elektrotechnik und Informationstechnik 
Institut:
EIT 1 - Institut für Plasmatechnik und Mathematik 
Professur:
Schein, Jochen 
Open Access ja oder nein?:
Ja / Yes 
Art der OA-Lizenz:
CC BY 4.0 
Sonstige Angaben:
arXiv preprint: 2412.04214